CalculatorsToolsGuides 日本語
BenchFig › Calculators › Delta-delta Ct (ΔΔCt) calculator: 2^−ΔΔCt fold change and P value
Free statistics calculators

Delta-delta Ct (ΔΔCt) calculator: 2^−ΔΔCt fold change and P value

Paste the group names and the target and reference Cq (Ct) values. The steps are the same as in the ΔΔCt guide and the Excel template, and statistics are run on ΔCt rather than on fold change.

Updated: BenchFig日本語

Your numbers are processed only in this browser. Nothing is sent to a server (it is gone when you close the page).

One row = one sample (biological replicate). Columns: group → target Cq → reference Cq (up to four reference genes, averaged). Put sample names (m1, m2…) in the second column to average technical-replicate wells of the same sample. Gene names in a header row are used in the sentence. Undetermined is treated as missing.

Two-group test

With three or more groups, each group is compared with the control by Dunnett’s multiple comparisons test (on ΔCt).

Table layout

Select a range like this in Excel, copy it and paste it in (a header row is optional).

GroupIL6GAPDH
Control30.1218.35
Control29.8518.52
Control30.4018.41
Treated25.7118.48
Treated26.0518.60
Treated25.4218.39

To paste technical replicates before averaging, add the sample name in the second column. Rows with the same group and sample are averaged.

GroupSampleIl1bActbGapdh
Vehiclem127.0518.0221.48
Vehiclem126.9117.9521.55
Vehiclem1Undetermined18.0721.51
Drugm124.4018.1021.60
……………

An empty group cell is read as the group above (merged cells in Excel). Analyse one target gene at a time. To work straight from instrument files, see from CFX data to a graph.

How it is calculated

  1. For each sample, ΔCt = target Cq − reference Cq (with several reference genes, subtract the arithmetic mean of their Cq values)
  2. Take the mean ΔCt of the control group: ΔΔCt = ΔCt − mean control ΔCt
  3. Fold change = 2−ΔΔCt. The group fold change comes from the group’s mean ΔCt (= the geometric mean of the sample fold changes)
  4. Statistics on ΔCt: two groups, a two-tailed t test; three or more, one-way ANOVA with Dunnett’s test against the control. ΔCt is on the log2 scale, which suits the test assumptions better than fold change

The 95% CI of the fold change is the CI of the ΔCt difference raised back to powers of 2, so it is not symmetric around the fold change (e.g. 22.0-fold, 14.2 to 34.2). The hand calculation is in the ΔΔCt method guide, with an Excel template.

Reading the results, and caveats

Key points
  • A fold change of 2 means twice as much, 0.5 means half. Down-regulation gives values below 1 (log2 FC −1)
  • n is the number of biological replicates (independent animals or cultures). Technical-replicate wells are averaged first and not counted in n
  • The ΔΔCt method assumes near-100% and equal amplification efficiencies for target and reference genes; otherwise use the Pfaffl method
  • The control fold changes do not average exactly 1 (their geometric mean is 1). This is expected

Check efficiency with a qPCR standard curve; for unequal efficiencies see ΔΔCt vs Pfaffl.

How it was checked

ΔCt, ΔΔCt, fold change, t, df, P and the fold-change 95% CI match an independent Python calculation (numpy, SciPy 1.18 ttest_ind and dunnett) for tables without headers, with decimal commas, with two reference genes, with technical replicates and Undetermined wells, and with a sample that has to be excluded. The example (22.0-fold, t(4) = 19.49, P = 4.1 × 10−5) matches the guide and the Excel template.

FAQ

Is my data sent anywhere?

No. Everything runs in your browser and the Cq values are never sent to a server. They disappear when you close the page.

Are Ct and Cq the same?

Yes. The MIQE guidelines recommend “Cq” (quantification cycle), which instruments such as the Bio-Rad CFX display.

Is the P value computed on fold change?

No, on ΔCt. Fold change is a ratio with a skewed distribution, so the usual practice is to test on ΔCt, the log2 scale (testing ΔCt or log2 fold change gives the same P).

What if I have two reference genes?

Paste both reference columns side by side. For each sample, the arithmetic mean of their Cq values is subtracted (a geometric mean in quantity terms, as in geNorm).

Student or Welch?

Student matches the Excel template (T.TEST type 2); use Welch if the ΔCt spread differs a lot between groups. With small experiments such as n = 3 per group, state which one you used in the methods.

From CFX files to graphs and statisticsLoad instrument files, check technical replicates, then ΔΔCt or standard curves and the graph. Try it with sample data.
Open for free →

Other calculators

Related guides

Product names are trademarks or registered trademarks of their respective owners.