IC50 / EC50 calculator (dose–response curve, 4PL)
A common way to get an IC50 in Excel is to draw a straight line between the two points either side of 50%. But dose–response data are S-shaped, and the IC50 should come from a fitted curve (4PL). Paste “concentration | response | response…” and this page fits the curve and gives the IC50 with a 95% confidence interval.
Your numbers are processed only in this browser. Nothing is sent to a server (it is gone when you close the page).
One row = one concentration. Replicates can be side by side or on repeated rows. Rows at concentration 0 are treated as the vehicle control (e.g. DMSO only) and included in the fit. A sideways table, as plate readers export it (concentrations across the first row), is turned upright automatically. A unit in brackets in the header, such as “(µM)”, is used in the chart and tables.
Inhibition: 100% is usually the mean of the vehicle control (concentration 0) and 0% the mean of background wells (medium only, no cells). Stimulation: 0% is the vehicle control and 100% e.g. the maximal response to a reference agonist.
Converting between pIC50 and IC50
pIC50 is the negative base-10 logarithm of the IC50 expressed in molar (M). A larger pIC50 means a more potent compound. Type into either box and the other is filled in.
pIC50 = −log10(IC50 [M]) IC50 [M] = 10−pIC50
| IC50 | In molar | pIC50 |
|---|---|---|
| 1 mM | 10−3 M | 3 |
| 1 µM | 10−6 M | 6 |
| 100 nM | 10−7 M | 7 |
| 10 nM | 10−8 M | 8 |
| 1 nM | 10−9 M | 9 |
- Watch the units: taking the log of an IC50 still in nM or µM is a common mistake (1 µM does not give −log10(1) = 0). Multiply by 10−6 for µM or 10−9 for nM first. In Excel, with an IC50 in µM in A2:
=-LOG10(A2*1E-6); the reverse, giving µM:=10^(-B2)*1E6. - A difference of 1 in pIC50 is a 10-fold difference in IC50: a pIC50 of 6 is ten times more potent than 5.
- The log10 IC50 in the calculator’s results table is the log in the unit you entered. If you entered µM, pIC50 = 6 − log10 IC50; for nM, 9 − log10 IC50.
- The same applies to EC50: pEC50 = −log10(EC50 [M]).
Table layout
Select the concentration and response columns in Excel, copy and paste. The response can be absorbance (MTT, WST and so on), luminescence, % inhibition or % viability.
| Conc (µM) | Abs 1 | Abs 2 | Abs 3 |
|---|---|---|---|
| 0 | 1.339 | 1.328 | 1.210 |
| 0.01 | 1.327 | 1.241 | 1.210 |
| … | … | … | … |
| 30 | 0.174 | 0.180 | 0.185 |
| 100 | 0.143 | 0.147 | 0.134 |
- Rows at concentration 0 are the vehicle control (vehicle only, no drug). They are included in the fit and used as 100% (inhibition) or 0% (stimulation) when converting to %.
- Replicates can be side by side or on repeated rows, and their number may differ between concentrations.
- A label column such as “D1, D2…” is fine. Blank and N/A cells are left out. Decimal commas (0,125) are understood.
- Enter concentrations, not log concentrations (convert log values first, e.g. =10^A2 in Excel).
The 4PL equation and the four values
The standard dose–response equation is (x = concentration, decreasing curve):
y = Bottom + (Top − Bottom) / (1 + (x / IC50)h)
| Value | Meaning | Example (converted to %) |
|---|---|---|
| Top | Upper plateau (the low-concentration end for inhibition) | 97.50% |
| Bottom | Lower plateau (the high-concentration end for inhibition) | 4.188% |
| IC50 (relative) | Concentration giving a response halfway between Top and Bottom (the 4PL parameter c, written EC50 in some equations); on a log concentration axis, this is where the curve is steepest | 1.758 µM |
| Hill slope h | Steepness, always positive in the equation above: 1 is standard, larger means a steeper S | 0.9693 |
The curve is fitted by the Levenberg–Marquardt method (nonlinear least squares) from several starting values, keeping the best fit. Replicates are fitted as individual points (not averaged first) and no weighting is used. The fitting code is the same as in the ELISA standard curve (4PL) calculator (in ELISA’s equation y = d + (a − d)/(1 + (x/c)b), c is the IC50 — the parameter called EC50 in equations such as GraphPad’s — and b is h; a and d are Top and Bottom for a decreasing curve, Bottom and Top for an increasing one).
Relative vs absolute IC50
“IC50” has two meanings, and papers mix them.
| Definition | Example | |
|---|---|---|
| Relative IC50 | Concentration halfway between the fitted Top and Bottom (the 4PL IC50). This is what “IC50” usually means | 1.758 µM |
| Absolute IC50 | Concentration giving exactly 50% (for inhibition with the vehicle control as 100%, half the vehicle control). Defined only for % data | 1.825 µM |
If the midpoint of Top and Bottom is 50% (for example, the curve falls cleanly from 100% to 0%), the two are the same. For an inhibition curve with Top = 100%, a Bottom above 0% (the drug never fully works) makes the absolute IC50 higher than the relative one (in general, the absolute IC50 is higher when the midpoint of Top and Bottom is above 50%, and lower when it is below). If the curve never crosses 50% (for inhibition, Bottom above 50%), there is no absolute IC50 at all. This page then gives no absolute IC50 and says why.
In the example, with the background (medium-only wells, 0.062) as 0%, Bottom = 4.19%, relative 1.76 µM and absolute 1.83 µM. Leaving 0% blank (a response of 0 = 0%) gives Bottom = 8.78% and moves the absolute IC50 to 2.04 µM, but the relative IC50 stays at 1.76 µM. How you convert to % changes only the absolute IC50. State clearly which one you report.
Converting to % and constraining Top and Bottom
- Fit as they are: fit the raw values such as absorbance. The relative IC50 and the Hill slope are the same whether or not you convert to % (the conversion only rescales the values).
- Convert to %: for inhibition, vehicle control = 100% and background = 0%; for stimulation, vehicle control = 0% and the maximal response to a reference agonist = 100%. Use this to show the curve in % or to get the absolute IC50.
- Already %: choose this when you have already calculated % inhibition or % viability.
For % data you can constrain Bottom = 0% and/or Top = 100% (three or two fitted parameters instead of four). When the curve does not reach its high-concentration plateau but the controls define 0% and 100% well, constraining stabilises the IC50. But if the drug truly does not reach 0%, forcing Bottom = 0 biases the IC50. In the example: no constraint 1.76 µM (95% CI 1.44–2.14), both constrained 1.85 µM (1.62–2.12). The methods sentence states any constraint automatically.
How the 95% CI is calculated
The 95% CI of the IC50 is symmetric on the log scale (a Wald interval on the log scale): IC50 × exp(± t × SE(IC50) / IC50), where t is the 97.5% point of the t distribution with df = number of points − number of fitted parameters. On the concentration scale the interval is asymmetric, longer on the upper side.
Concentrations are usually spaced evenly on a log scale and IC50 uncertainty is naturally “how many fold”, so the log scale suits it better than IC50 ± t × SE on the concentration scale (which can even give a negative lower limit). The table also shows log10 IC50 and its standard error, which we checked equals the value from fitting log10 IC50 directly as a parameter.
IC50 outside the tested range, or no plateau
If the IC50 is below the lowest or above the highest concentration tested, it comes from extending the curve: an extrapolation. This page labels it “extrapolated” and warns you. Report it as “> highest concentration” or “< lowest concentration”, or widen the concentration range and repeat.
If the curve has not levelled off at high concentrations (the response is still falling), Bottom is not determined and the IC50 and its CI can move a lot. The page warns when the curve has covered less than 80% of the way to the high-concentration plateau, and when the 95% CI spans more than a 10-fold range.
- Use 8–10 concentrations evenly spaced on a log scale (e.g. 3-fold) around the IC50
- Go far enough to see both plateaus (no effect and full effect)
- Always include the vehicle control (concentration 0)
- A high R² is expected; look at the CI width and whether the curve follows the points
Getting an IC50 in Excel: a caution
Excel’s trendlines have no 4PL, so a common approach is to join the two concentrations either side of 50% with a straight line and read off where it hits 50%. With the example (in %), joining 1.00 µM (65.0%) and 3.00 µM (37.8%) gives 2.10 µM when interpolating on the concentration scale and 1.83 µM on the log scale, compared with the 4PL absolute IC50 of 1.83 µM. Only two points are used, so their noise goes straight into the IC50, and there is no confidence interval.
You can fit a 4PL with Solver, but it can land on a different answer depending on the starting values. Here you just paste, and “Copy the tables” gives results you can paste back into Excel. To compute the absolute IC50 in Excel from the 4PL parameters of a decreasing curve: =IC50*((Top-Bottom)/(50-Bottom)-1)^(1/h) (h positive, only when Bottom < 50 < Top).
How it was checked
The IC50, Hill slope, Top and Bottom with their standard errors and 95% CIs, the log-scale CI of the IC50, R² and the absolute IC50 match an independent Python calculation (SciPy 1.18 curve_fit, same equation and points) to a relative error below 10−5 for the parameters. Twelve cases were checked: the example (raw, converted to %, four combinations of Top/Bottom constraints), a stimulation curve (luminescence, converted to %, Bottom constrained, both constrained) and % data without a high-concentration plateau (IC50 outside the range). Constrained fits were compared with curve_fit on the equation with the fixed parameters removed; the absolute IC50 was compared with a numerical search for where the curve crosses 50%.
For the example (converted to %, no constraints): IC50 = 1.758 µM (95% CI 1.44–2.14 µM), Hill slope 0.969, R² = 0.9910. Fitting the raw absorbance gives the same IC50 = 1.758 µM.
Only 4PL is available for now; 5PL (an asymmetric S-curve), comparing IC50s between curves (a test of difference) and weighting are not supported.
FAQ
Is my data sent anywhere?
No. Everything runs in your browser and your concentrations and responses are never sent to a server. They disappear when you close the page.
How do I calculate an IC50 in Excel?
Excel has no 4PL trendline, so people often join the two points either side of 50% with a straight line. That uses only two points, is noisy and gives no confidence interval. Paste your data here to get a 4PL IC50 with a 95% CI, and paste the result tables back into Excel.
What is the difference between IC50 and EC50?
The IC50 is the concentration that inhibits a response by half (typical for inhibitors and antagonists); the EC50 is the concentration that produces a response halfway between baseline and maximum (typical for agonists and stimulators). Only the direction of the curve differs; the 4PL calculation is the same. On this page, choosing the direction changes the labels and the methods sentence.
How do I convert pIC50 to IC50?
IC50 [M] = 10^(−pIC50). Multiply by 10^6 for µM or 10^9 for nM (pIC50 6.5 → 0.316 µM = 316 nM). The converter at the top of this page does it for you.
Should I report the relative or the absolute IC50?
Usually the relative IC50 (the 4PL IC50). Use the absolute IC50 when you want “the concentration giving 50% viability”. They differ whenever the midpoint of Top and Bottom is not 50%, so say which one you used.
Should I constrain Bottom = 0 and Top = 100?
If the controls define 0% and 100% well and the curve does not reach a plateau, constraining stabilises the IC50. If the drug truly does not reach 0%, do not constrain, because it biases the IC50.
My IC50 is outside the concentration range
It is an extrapolation from extending the curve. Avoid reporting it as a value; write “> highest concentration” or widen the range and repeat.
Other calculators
Related guides
Product names are trademarks or registered trademarks of their respective owners.