From qPCR data (Bio-Rad CFX and others) to a graph

Getting from qPCR results to a graph involves exporting Cq values, checking technical replicates, normalizing to a reference gene, summarizing by group and testing, which usually means many trips through Excel. Using CFX result files as the example, this guide walks through the whole path in BenchFig, from import to a publication figure.

Updated: BenchFig日本語

The workflow

  1. Export Quantification Cq Results from CFX Manager / CFX Maestro as CSV or Excel
  2. Open it on BenchFig’s qPCR screen
  3. Check the method, reference genes, control group and sample grouping
  4. Review technical-replicate outliers and NTCs, and exclude wells if needed
  5. Look at the results (relative expression for ΔΔCt, relative quantity for a standard curve) and open them as a graph
  6. Choose a test, add the graph to a figure and export to the journal’s requirements
Key points
  • Use the “Quantification Cq Results” table from CFX (CSV or .xlsx)
  • Average technical replicates first; n is the number of biological samples
  • Test on log2-transformed values, not on fold change itself
  • For repeated experiments, load one file per run and test on run means

1. Export results from CFX

In CFX Manager or CFX Maestro, use the data export of the analysis window to save the Quantification Cq Results table, which lists the Cq of every well, as CSV or Excel. Other tables (such as raw amplification data) are not needed. These are the columns BenchFig reads:

ColumnContentsNeeded?
WellWell position (A01 …)Well or Target required
TargetGene name (IL6, GAPDH …)Well or Target required
SampleSample name (Control 1 …)Used for grouping
ContentType: Std / Unkn / NTCOtherwise inferred from starting quantity
CqCq (Ct) valueRequired
Starting Quantity (SQ)Quantity of standardsFor the standard-curve method
First four rows of BenchFig’s ΔΔCt sample file (CFX format, made-up data), showing only the columns used.
WellTargetContentSampleCqCq Mean
A01IL6Unkn-01Control 130.3430.37
A02IL6Unkn-01Control 130.4130.37
A03IL6Unkn-01Control 130.3630.37
A04IL6Unkn-02Control 229.8329.88

CFX also writes a Cq Mean for each replicate group, but BenchFig recomputes the mean from the individual wells so that excluded wells are taken into account.

2. Open the file and check the settings

Choose “Open CFX file”. BenchFig shows the number of wells, targets and samples, and guesses the settings.

3. Check outliers and NTCs

In the “Wells” table, a well farther from its replicate median than the “Replicate tolerance (Cq)” is flagged “Outlier?”, a pair of wells that disagree is flagged “Large spread”, wells without a Cq are “No Cq”, and amplification in a no-template control is “NTC amplified”. Exclude only wells with a likely technical cause, such as a pipetting error. “Exclude flagged wells” removes them all at once, but record the reason in your lab notebook.

With the standard-curve method, check slope, intercept, R² and efficiency in the “Standard curves” tab. Efficiency outside 90–110% or R² below 0.98 produces a warning.

See the outlier flags on a sample file“Sample: standard curve” includes an outlier well and NTCs.
Open for free →

4. Graph and test the results

The “Results” tab lists ΔCt, ΔΔCt and relative expression (or relative quantity) for each sample, with a summary per group. “Open this target as a graph” sends the group values to the graph screen.

5. Combine repeated experiments

If you ran the same experiment on three days, open all three files at once with “Combine runs” (one file = one run). Sample and gene names are matched automatically, ΔΔCt is computed within each run, and statistics use the run means (n = number of runs). The result can be drawn as a SuperPlot, with small points for samples and large points for run means. The reasoning is explained in Graphing repeated experiments with SuperPlots.

Build a SuperPlot from three sample runs“Sample: 3 experiments” covers per-run analysis, testing on run means and the SuperPlot.
Open for free →

6. Assemble and export the figure

Click “Add to figure” on a graph or qPCR result to place it as panel A, B, C… in a single figure. Choosing a journal adjusts width, font size and line weights to its requirements (see journal figure requirements). Exporting PDF, TIFF, PNG and SVG and saving results as CSV are features of the Windows app.

FAQ

Can I load files from other instruments (QuantStudio, LightCycler…)?

Any CSV or Excel (.xlsx) table with a well (or target) column and a Cq (Ct) column can be loaded through “Choose columns”, where you tell BenchFig which column is which. Common variants such as Ct, Cp or Sample Name are usually recognized automatically. Not every instrument-specific format has been verified, so try the sample closest to your file in the free trial first.

Can I open legacy .xls files?

No. Please save as .xlsx or CSV.

What happens to wells marked Undetermined or NaN?

They are treated as “No Cq” and left out of averages, with a flag in the wells table. Amplification in an NTC is flagged “NTC amplified” with a warning.

How do I use my own data?

The free trial lets you try the screens and features with sample data. Loading your own files, saving your work and exporting PDF/TIFF/PNG/SVG/CSV come with BenchFig Pro for Windows (annual or perpetual license).

Take a sample CFX file all the way to a graphThree samples: “Sample: ΔΔCt”, “Sample: standard curve” and “Sample: unusual columns”. Import, analysis, graph and statistics in the browser.
Open for free →
Your own data, all the way to the final figure.Loading your files, saving, and journal-ready export (PDF, TIFF, PNG, SVG) are in BenchFig Pro for Windows, updated based on researchers’ requests: ¥3,980/year (2 PCs), with lab and perpetual licenses too.
About the app →

Related guides

Product and journal names are trademarks or registered trademarks of their respective owners.